Scan 1200 is an HD automatic colony counter. It adapts itself to all media and counts in 1 click all colonies even the smallest ones. It ensures accuracy and excellent reproducibility. Images and results are saved automatically. Scan 1200 is also an inhibition zone reader.
- Minimum size of detected colony: 0.05 mm
- Camera: 1.2 megapixels - zoom x 28
- Counting on Ø 55 - 90 mm round Petri dishes
- Counting on pour, surface, Spiral, circle mode plated Petri dishes
- Counting on chromogenic agar, PetriFilmTM, MC-media PadsTM, Compact DryTM, Easy PlateTM, filtration membranes
- Inhibition zone reader
Large reading range
The Scan 1200 allows reading on Ø 55 - 90 mm Petri dishes and works with numerous media and supports. Scan 1200 reads also inhibition zones on round Petri dishes.
Colony counting
Inhibition zone reading
Accuracy and repeatability
The counting of Petri dishes is long, tedious and can vary from one person to another.
The Scan 1200 can count up to 1000 colonies in 1 second in a constant and repeatable mode. Counting accuracy reach up to 98%. The minimum colony size is 0.05 mm.
21 CFR Part 11 included
The Scan software complies with FDA recommendations, particularly on audit trail and security of results.
The user account management, integrated in the software, allows the creation of up to 5 levels of rights. The Supervisor-Administrator has all the roles while the other roles are subject to certain rights. Password management secures user accounts.
Traceability
Data import
Scan 1200 connects to the LIMS in bi-directionality and can be connected to the diluter and plater via dataLink traceability system.
Data recording
After each approved counting, the Scan 4000 automatically saves and exports the counting parameters and results to a CSV file.
Data export
Scan 1200 offers multiple export possibilities to save manual input time. It also increases the security and quality of your analyses.
Usually, Petri dishes are thrown away after counting and no further verification is possible in the event of a claim. With Scan 1200, all reports are archived.
Export your results to your PC or archive them in CSV, ExcelTM, OpenOfficeTM, PDF, SCA, BIO format. You can also export images from the camera in JPEG, PNG and BMP format.
Print of the results
All data, images, photos and results are exportable in printable reports, sca, pdf, jpg, xls, csv.
Dark Field lighting technology
Thanks to the Dark Field technology and its low lighting, colonies are easy to count. The operator does not tire his eyes.
Ideal with dataLink full traceability system
dataLink is a complete traceability system for the microbiological analysis of a sample, from its plating with easySpiral Pro or easySpiral Dilute platers to colony counting. After incubation, the reading of the datamatrix code makes it possible to collect the information of the sample and its plating and to automatically launch on the colony counter the associated parameters.
Warranty
Scan 1200 automatic colony counters have 3-YEAR warranty (parts and labour) just by sending the warranty card back.
Applications
The Scan 1200 colony counter is used in the food, environmental, pharmaceutical, cosmetics, veterinary and public institutes research.
Specifications
|
Scan 1200 |
Reference |
437 000 |
Type of colony counter |
Automatic |
Camera |
HD CCD color camera |
Lens |
HD japanese lens |
Zoom |
x 28 |
Resolution |
1.2 megapixels |
Counting time |
Up to 1000 colonies per second |
Minimal size of colony |
0.05 mm |
Lighting technology |
Long-life white LEDs / Dark Field |
Lighting system |
Automatic with 6 combinations, top and/or bottom light, white or black background |
Counting |
Automatic with manual control |
Counting on Petri dishes |
Ø 55 mm - Ø 90 mm |
Counting on PetriFilmTM |
Automatic |
Counting on MC-Media PadsTM |
Automatic |
Counting on Compact DryTM |
Automatic |
Counting on Easy PlateTM |
Automatic |
Counting on filtration membranes |
Automatic |
Colony counter |
Yes |
Inhibition zone reader |
Yes |
Counting on pour, surface, Spiral and circle plated Petri dishes |
Yes |
Counting on chromogenic dishes |
Yes |
Automatic separation of clustered colonies |
Yes |
Creation of polygonal exclusion zones |
Yes |
Manual control to add or substract colonies |
Yes |
LIMS connection |
Yes |
USB connection |
Yes |
Available with dataLink traceability system |
Yes |
Stainless steel |
Yes |
Color detection |
7 colors on the same dish + 1 color to exclude |
Data export |
Recountable session, PDF, jpg, png, bmp, ExcelTM |
Data security |
Modified data traceability in conformity with 21 CFR part 11 / Connexion with LIMS/SIL systems |
Results/traceability |
Image / sample number / comments / date / time |
Languages |
English, French, Japanese, Chinese, Russian, Spanish, German |
Dimensions (w x d x h) |
28.5 x 26.5 x 37.5 cm |
Net weight |
9.4 kg |
Box (w x d x h) |
57 x 42 x 42 cm |
Gross weight |
12.4 kg |
Voltage - Frequencies |
100-240 V~ 50-60 Hz |
Power |
20 W |
International protection marking |
00 |
Operating sytem |
WindowsTM : 8 or 10 |
Processor |
Intel i3 or better, 2.8 GHz, quad core recommended |
RAM |
4 GB (2 GB of RAM must be reserved for the exclusif use of the Scan) |
Equipments |
USB 2.0 port free |
Screen |
1280 X 1024 pixels or superior |
Software update |
3 years |
Warranty |
3 years |
In compliance with |