C 200
C 200-System consists of the following components:
- Measuring cell C 200
- Decomposition vessel C 5010
- Oxygen filling station C 248
- Consumables for calibrations and installation
Space-saving and low cost combustion calorimeter for determing gross calorific values of liquid and solid samples.
Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
Suitable for teaching and training, as well (f.e tecnical- schools, universities) and for industriell laboratories with less analyses..
Manual handling for water and oxygen filling.
Four different working methods, isoperibolic, dynamic, manual, time controlled makes possible an ideal adjustment of different operating tasks.
Clear and easily explained display which is simply to use .
With an external power pack, "world tension useable" from 100 - 240 V AC, 50/60 Hz. The operating voltage of the calorimeter is 24 V DC low- voltage.
Friendly in aftersales
Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself; the temperature increase will be indicated at the display each minute.
All calculations have to be done manually.
At the other three modes ignition and calculation of the gross calorific value will be done automatically.
The gross calorific value will be shown on the display. Acid corrections and calculations of the net calorific value have to be done manually.
The modes have different measuring times:
Isoperibolic: approx: 17 min.
Dynamic : approx. 8 min
Manual : approx. 17 min
(depend on the operator)
Time controlled : 14 min
The decomposition vessel can be equiped in to use an combustible crucibles C 14
(accessory C 5010.4 attachment is neessary)
User-friendly software C 6040 Calwin for controlling the calorimeter and administration of measuring data (asseccory). Transfer of the datas to Excel or Word are possible
Up to eight IKA measuring cells can be controlled by a single PC, using a multiserial plug in card PCI 8.2 (accessory)
C 200 h
The C 200 h package is designed for teaching and training purposes at technical schools and universities. Due to its semi-automated isoperibol mode it is also perfectly suitable for industrial laboratories with low number of analyses. The space-saving and standard-conforming combustion calorimeter determines the gross calorific value of liquid and solid samples.
The water and oxygen handling is conducted manually. In case of an increasing amount of measurements the water handling system can be further automated. For that purpose, the C 200.RC hose set as well as the RC 2 basic recirculating chiller are required. Both accessories are available separately.
The catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and/or sulfur is required after the combustion.
Four different operation modes enable the user to control the measuring times according to individual requirements:
Isoperibol: approx: 17 min.
Dynamic: approx. 8 min
Manual: approx. 17 min (depends on the operator)
Time controlled: 14 min
Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately.
C 200 auto
The C 200 auto package allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results.
The semi-automated and conforming to standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses.
Four different operation modes enable the user to control the measuring times according to individual requirements:
Isoperibol: approx: 17 min.
Dynamic : approx. 8 min
Manual : approx. 17 min (depends on the operator)
Time controlled : 14 min
Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The software C 6040 Calwin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. Calwin is sold separately.
C 200 h auto
The C 200 h auto package allows operating the C 200 with a completely automated water cycle. This results in ease of handling and saves valuable time especially for laboratories with a low number of analyses. The water circulates in a closed loop and is kept at a constant temperature by using a recirculating chiller. This leads to shorter preparation time for each experiment and even better reproducible results.
The semi-automated and conforming-to-standards combustion calorimeter determines the gross calorific value of liquid and solid samples. So far it has mainly been used for teaching and training purposes at technical schools and universities. Due to the automated water handling it is now also suitable for industrial laboratories with low number of analyses.
The catalytic activated, halogen resistant decomposition vessel C 5012 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). The material of the decomposition vessel (Hastelloy) prevents corrosion caused by samples with high chlorine content. The catalytic activated inner-surface leads to higher recovery rates in case analysis of halogens and/or sulfur is required after the combustion.
Four different operation modes enable the user to control the measuring times according to individual requirements:
Isoperibol: approx: 17 min.
Dynamic: approx. 8 min
Manual: approx. 17 min (depends on the operator)
Time controlled: 14 min
Measurements are possible according to e.g. DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The software C 6040 CalWin controls the unit and monitors the measurement of the samples. Additionally, collected data can be exported to e.g. Excel, Word, SQL and LIMS for further analysis. It is possible to operate several calorimeters with one PC. A PC is not part of the scope of delivery and needs to be provided by the operator. CalWin is sold separately.