Overview
High throughput, fully automated staining and coverslipping process. Quality control system embedded and ready-to-use consumables, and patented AAT system keeps each slide consistent.
Features
Combo system: The future of pathology's workstation
High throughput, fully automated staining and coverslipping process. Quality control system embedded and ready-to-use consumables, and patented AAT system keeps each slide consistent.
Expertise in quality control, excellent staining effect
Patented AAT system
AAT technology keeps staining consistent according to the specimen / numbers of staining rack and /or days of hematoxylin and eosin use, the soaking time will be gradually increased to achieve staining consistency.
This system saves on the reagent cost.
Reagent Management: quality control
The Software controls the reagent management system. It allows the users to monitor reagent utilization and automatically generates a replacement reminder. This report enables effective traceability and management of staining quality and helps to reduce reagent costs.
Reduce reagent carry over and cross contamination
The powerful robotic arm has the function of " leaching" and "shaking" .The slide stainer can effectively reduce reagent carry over and limit cross contamination.
High speed robotic arm
The robotic arm is quick and silent . Its vertical pulling speed can be as fast as 0.76 m/s. It allows up to 11 slide racks to run at the same time. The staining time is always accurate.
High throughput, high efficiency
High-throughput staining and coverslipping
The innovative intelligent software algorithm is able to handle approximately 360 slides per hour (depending on the user protocols).
On Combo mode, the transfer process is managed inside the CS500 without additional transfer station.
CS500 Automated inspection
The device’s performance and reagent status are automatically checked before each run. The damaged coverslips are automatically identified . The CS500 has a micro-pump which delivers the exact mounting media, to prevent spillage. To avoid needle blockage, the needle will be automatically self-cleaned once coverslipping is completed.
Horizontal Slide tray output
No manual transfer is needed, which allows for convenient image reading.
Flexibility
Enter up to 100 protocols
2 Pre-programmed protocols : H/E staining, PAP staining.
Flexible reagent solution
Optional exclusive ready-to-use reagent supplies for better results.
Reagent heating station
The reagent can be slightly heated to eliminate the impact of climate differences and save reagent costs.
QC for each slide
Scientific management for reagents
-
Reminder or forcible execution for reagents renewal.
-
Historical renewal records can be checked at any time.
-
Graphic reports of SOP can be exported directly.
-
Statistics of reagents consumption.
Human-computer interaction is intuitive
Display indicates the status of the Stainer and coverslipper, the current reagent status and the amount of slides that have been completed.
Remote real-time monitoring, alarms and queries
DAKEWE cloud remote monitoring system allows real-time monitoring of instrument status and remote warning (through webpage, email, SMS, and other ways), for effective management of equipment and enhanced tissue safety.
Safety and ergonomic
Unique interaction
25 cm (10.4 inch) color touch display, user-friendly software design, simple operation process.
Total safety
The intelligent exhaust gas monitoring function ensures that fumes do not escape. The exhaust gas concentration sensor monitors in real-time to protect staff's health.
Various alarms
Real-time voice, visual signals, text, and notification via application provide an intelligent operating guide program.
Specifications
DP360 Technical Specifications |
Dimensions, unpacked (W x D x H) |
1066 x 700 x 630 mm |
Net Weight |
approx.130 kg |
Power consumption |
1200 VA |
Supply voltage/ frequency |
100 - 240 VAC 50/60 Hz |
Operating temperature range |
+15°C to +40°C |
Total stations |
26 |
Oven station and temperature |
1; Max temperature 75°C |
Reagent heating station |
4; Max temperature 38°C |
Water washing station |
4 |
Reservoir volume |
480 ml ± 20 ml |
Program storage capacity |
≥100 programs |
Slide rack capacity |
30 pcs |
Throughtput H/E |
360 slides per hour |
CS500 Technical Specifications |
Dimensions, unpacked (W x D x H) |
660 x 770 x 640 mm |
Net weight |
approx.90 kg |
Power consumption |
180 VA |
Supply voltage/ frequency |
100 - 240 VAC, 50/60 Hz |
Horizontal output storage |
90 pcs |
Coverslip capacity |
200 pcs |
Mountant bottle capacity |
250 ml |
Throughput |
360 slides per hour |
Coverslip sizes ( mm) |
24 x 50 |