Overview
Product name: |
Human Ab1-40(Amyloid Beta Peptide 1-40) ELISA Kit |
Reactivity: |
Human |
Alternative Names: |
Amyloid Beta Peptide 1-40 |
Assay Type: |
Sandwich |
Sensitivity: |
4.58 pg/mL |
Standard: |
1000 pg/mL |
Range: |
15.63-1000 pg/mL |
Sample Type: |
Serum, plasma and other biological fluids |
Assay Length: |
3.5h |
Research Area: |
Infection immunity;Neuro science; |
Test principle: |
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Ab1-40. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Ab1-40. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Ab1-40, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Ab1-40 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) |
OD |
Corrected OD |
1000.00 |
2.082 |
1.987 |
500.00 |
1.621 |
1.526 |
250.00 |
0.997 |
0.902 |
125.00 |
0.765 |
0.670 |
62.50 |
0.503 |
0.408 |
31.25 |
0.351 |
0.256 |
15.63 |
0.221 |
0.126 |
0.00 |
0.095 |
0.000 |
Precision
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant Ab1-40 and the recovery rates were calculated by comparing the measured value to the expected amount of Ab1-40 in samples.
Matrix |
Recovery range |
Average |
serum(n=5) |
80-94% |
87% |
EDTA plasma(n=5) |
89-101% |
95% |
Heparin plasma(n=5) |
82-95% |
88% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ab1-40 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix |
1:2 |
1:4 |
1:8 |
1:16 |
serum(n=5) |
89-97% |
86-102% |
94-106% |
85-97% |
EDTA plasma(n=5) |
85-97% |
93-106% |
83-95% |
88-103% |
Heparin plasma(n=5) |
95-103% |
88-96% |
81-95% |
91-102% |