Overview
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required to read the absorbance at 545nm.
Product information
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required for the assay. The purple items are proportional to endotoxin concentration. Then endotoxin testing result is quantitative analysis.
Product parameter
Sensitivity Range: 0.01-0.1EU/ml (assay time about 46 minutes)
0.1-1.0EU/ml (assay time about 16 minutes)
Catalog No. |
Description |
Kit Contents |
Sensitivity EU/ml |
EC80545
|
Bioendo™ EC Endotoxin Test Kit
(End-point Chromogenic Assay,
Diazo Coupling),
80 Tests/Kit
|
5 Lyophilized Amebocyte Lysate, 1.7ml/vial;
4 Water for BET, 50ml/vial;
5 CSE;
5 Chromogenic Substrate, 1.7ml/vial;
5 Diazo Reagent 1, 10ml/vial;
5 Diazo Reagent 2, 10ml /vial;
5 Diazo Reagent 3, 10ml/vial
|
0.1 – 1 EU/ml
|
EC80545S
|
0.01 – 0.1 EU/ml;
0.1 – 1 EU/ml
|
Product features and application
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into Lyophilized Amebocyte Lysate, and then test specimen mixture. If specimen contains endotoxin, color of specimen mixture changes. The absorbance is related to the endotoxin concentration. Therefore the endotoxn levels in specimen mixture can be claculated against a standard curve. Standard spectrophotometer with 540 – 545nm filter is enough to quantify endotoxin with our EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling).
Note
Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.
Product condition
The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.
Does the End point endotoxin test kit need sophisticated microplate reader?
Bioendo EC80545 and EC80545S, can read by regular spectrophotometer.
End point chromogenic endotoxin test kit series:
- Endotoxin Free Tube
- Pyrogen Free Tips
- Pyrogen Free Microplates
- normal Microplate reader
- Water Bath or Dry Heat Incubator