[Outstanding Performance]
Two performance capabilities supporting data reliability: excellent reproducibility made possible by the pump and autosampler and excellent stability of the column oven and detector.
[Easy-to-use]
Along with simple operation and ease of use, Chromaster offers ease of maintenance, a critical requirement for HPLC.
[Robustness]
Hitachi's reputation for instrument robustness and reliability continues with the Chromaster, which is built using stronger materials and manufactured with Hitachi's strict quality control standards.
Features

*1:Optional

*1:Optional
*2: Autosamplers with or without thermostat are available
*3: Pumps with or without Auto-purge valve are available

Module Lineup
Pump
5110: Pressure up to 40 MPa
5160: Pressure up to 60 MPa
Basic UHPLC models with a wide range of HPLC application
Item |
5110 |
5160 |
Operating flow late range |
0.001 to 9.999 mL/min |
0.001 to 5.000 mL/min |
Maximum operating pressure |
40 MPa (0.001 to 5.000 mL/min)
20 MPa (5.001 to 9.999 mL/min) |
60 MPa (0.001 to 2.500 mL/min)
30 MPa (2.501 to 5.000 mL/min) |
Dimensions |
340(W) × 440(D) × 140(H) mm |
Number of mixed solvents*1 |
Up to 4 |
*With low pressure gradient unit (optional)
Autosampler
5260: Withstand pressure 60 MPa, Loop injection method
5280: Withstand pressure 60 MPa, Direct injection method
Product lineup to accommodate various applications
Item |
5260 |
5280 |
Sample injection system |
Loop injection method (Cut injection, All volume injection, Full loop injection method) |
Direct injection method |
Withstand pressure |
60 MPa |
60 MPa |
Washing function |
Equipped with built-in washing pump
Two-solvent washing function |
Wash solvent delivery by a syringe |
Sample rack temperature control |
1 to 45 °C |
1 to 35 °C |
(Temperature setting range) |
Capable of cooling and heating |
Cooling only |
Sample capacity |
Standard |
120 × 1.5 mL |
200 × 1.5 mL |
Optional |
72 × 4 mL |
128 × 4 mL |
Column Oven
5310: Horizontal type
6310: Vertical type
Easily accommodates a 300-mm analytical column fitted with a guard-column
tem |
5310 |
6310 |
Temperature setting range |
1 to 85 °C (1 °C step) |
4 to 90 °C (1 °C step) |
Temperature control range |
[Ambient temperature -15 °C] to [Ambient temperature +60 °C] and range of the temperature setting |
[Ambient temperature -15 °C] to [Ambient temperature +75 °C] and within temperature setting range |
Column capacity |
300 mm × 3 (Maximum) |
Built-in 3-liter water tank |
- |
Available |
Dimensions |
410(W) × 440(D) × 140(H) mm |
165(W) × 515(D) × 689(H) mm (Legs are not included) |
Detector
5410: UV Detector
5420: UV-Vis Detector
5430: Diode Array Detector
5440: Fluorescence Detector
5450: RI Detector
5610: MS Detector