Features
COMPACT!
- All components are integrated in a small footprint of 31 cm (W) x 27 cm (D).
- Saves valuable bench space.
FLEXIBLE!
- Performs acid/base, redox, precipitation and complexometric titrations.
- Combining optional KF kit, performs Karl Fischer moisture determination.
- A wide selection of electrodes
POWERFUL!
- 30 user defined methods plus 3 KF methods can be stored in memory and easily recalled according to samples.
- Up to 50 results with titration curve can be stored with statistics calculation.
SATISFACTION!
- Equipped with two RS-232C ports for balance and computer connection.
- Standard package includes AQUANet data download software, instruction movie, application guidebook and more.
*Generally a company name printing in this catalogue and a product name are a trademark of the company or registered trademarks.
*The product color may vary from the actual product due to printing qualities.
*Appearance, specification, etc. are subject to change for improvement without prior notice.
Note: For safe and appropriate use, please be sure to read the "Instruction Manual" before using the product.
Specifications
Item |
Description |
Titration method |
Standard:Potentiometric titration
Optional:Photometric titration, Volumetric Karl-Fischer titration |
Measuring Range |
pH: 0 to 14, Resolution 0.01pH
mV: -2,000 to +2,000 mV, Resolution 0.1 mV |
Electrode Inputs |
Indicator electrode: 1
Reference electrode: 1
Thermistor electrode: 1
Electrode for KF titration: 1 |
Titration steps |
Up to three(3) steps |
Number of Endpoints |
Up to two(2) points |
End point detection |
Automatic detection by:
-Inflection point
-Set point
-F cross point
-B cross point
Meas.(pH measurement)
Disp.(dispensing) |
Display |
16-Digit x 2-Line LCD with backlighting |
Display unit |
pH, mV, mL, mgH2, %, ppm, M, g/L, mg/g, Fact 1, Fact 2 |
pH calibration |
2 or 3 points (compliant to ASTM or other standard buffers) |
File function |
30 files for potentiometric titrations
3 files for Karl-Fischer titrations
10 files for titration control methods |
Calculation function |
Concentration calculation, Statistics calculation |
Memory data capacity |
50 titration results along with titration curves and parameters and via external computer |
Precautions against power failure |
Built-in backup battery |
Electrodes (Standard component) |
· RE-201Z Glass electrode
· RE-201 Reference electrode
· TE-401 Thermistor electrode |
Buret |
Capacity: 20mL, Minimum drop size: 0.005 mL
Reproducibility: within ±0.01 mL |
Tubing |
PTFE tube of 2 mm(ID) and 3 mm(OD) |
Switching Valve |
Automatic switching valve with ceramic joint. |
Stirrer |
Integrated, variable speed, magnetic stirrer |
Printers |
Optional impact printer; PR-302B |
External input / output |
RS-232C; 2 ports
Port 1 (BALANCE):For connection to electronic balance.
Port 2 (HOST):For connection to external computer. |
Power supply / Power consumption |
AC100 - 240 V, 50/60 Hz, 100 VA |
Dimensions / Weight |
310(W) × 270 (D) × 310 (H) mm
Approx. 7 kg |
*Generally a company name printing in this catalogue and a product name are a trademark of the company or registered trademarks.
*The product color may vary from the actual product due to printing qualities.
*Appearance, specification, etc. are subject to change for improvement without prior notice.
Note: For safe and appropriate use, please be sure to read the "Instruction Manual" before using the product.
Options
- Dot Impact Printer PR-302B (Paper width: 58 mm)
- Buret B-130
- Stirrer K-2000A2S
- Karl Fischer Titration Kit
*Generally a company name printing in this catalogue and a product name are a trademark of the company or registered trademarks.
*The product color may vary from the actual product due to printing qualities.
*Appearance, specification, etc. are subject to change for improvement without prior notice.
Note: For safe and appropriate use, please be sure to read the "Instruction Manual" before using the product.