The lid can be opened, closed and locked easily and securely. Equipped with a safety function that locks the lid by detecting pressure and temperature. Equipped with various functions including culture medium dissolution. We also offer a variety of options.
A forced cooling fan is an optional unit.
[ Model / Effective capacity ]
HV-50 HV-85 HV-110
Features & Functions
Electro-mechanical lid lock system
Dual interlock mechanism
Air removal time setting
Forced cooling unit(option)
Electro-mechanical lid lock system
The lid can be opened and closed easily and reliably with the one-touch lever.
A pressure seal method is used as a safety measure.
Dual interlock mechanism
The lid is locked by dually detecting the chamber pressure and chamber temperature during operation.
The lock state is maintained even if an operation is manually interrupted.
Dual detection system for residual air
The residual air which may cause sterilization failure is dually detected to always maintain the appropriate sterilization conditions for loads.
The residual air is detected at the process before pressurization (during operation of an air removal timer) and at the process of pressurization air exhaust.
Exhaust level can be set digitally.
Fine exhaust can be performed automatically, and fine exhaust adjustment is possible even in exhaust.
Memory function
Set contents can be registered for each mode.
EU model available
EU Model: Products compliant with european Standards (ENs)
Operation Cycle of Each Mode
MODE 1:
LIQUID with warming
Heating
Sterilization
Variable exhaust
Warming
Main applications: Sterilization of agar medium (It is warmed at constant temperature to prevent clotting after sterilization.)
MODE 2:
LIQUID without warming
Heating
Sterilization
Variable exhaust
Main applications: Sterilization of liquid, which can withstand high temperature and high pressure steam such as water, culture medium, reagent, reagent solution, liquid medicine, etc. and sterilization of waste using a sterilization bag.
MODE 3:
SOLID
Heating
Sterilization
Forced exhaust
Main applications: Sterilization of instruments made of glass, ceramic, metal or rubber that can withstand high temperature, high pressure steam and rapid pressure reduction during exhaust.
MODE4:
DISSOLUTION
Heating
Warming
Main applications: Dissolution of agar medium (It is warmed at constant temperature to prevent clotting after heating.)
Options for Upgrading a System
Forced cooling unit (air-cool)
Floating sensor
Recorder
Printer
Automatic
water supply
Used to shorten the time to unloading after sterilization
A sterilization timer operates after the temperature of the materials to be sterilzed reaches the set temperature.
(Image is a chart type recorder.)
Chart type recorder: 6-point dotting
Hybrid recorder: 8-point dotting
Chart width: 100 mm
Class 2 T-type thermocouple included
Thermal print type
Manual water supply to the chamber becomes unnecessar
Option
Stainless steel round wire basket
Sterilization bucket, stainless steel
[For HV-50]
φ270 x H220 mm
φ270 x H270 mm
[For HV-85]
φ380 x H285 mm
[For HV-110]
φ380 x H375 mm
[For HV-50]
φ270 x H220 mm
φ270 x H270 mm
[For HV-85 - with holes / without holes]
φ380 x H285 mm
[For HV-110 - with holes / without holes]
φ380 x H375 mm
Detergent for autoclave
Sterilization bag
Deodorizer
Detergent to remove culture media, water scale sticked to the inside of a chamber
[Standard amount of use]
1 cap of detergent in 2 L of water (20 ml - 1%)
Take out the materials at the time of use.
500 ml
Special structure reinforced film.
Heat resistant temperature is 130°C
[Type: A] 200 pcs
500 x 700 mm
[Type: B] 200 pcs
620 x 820 mm
Use it without closing the mouth.
Deodorizer for the "unpleasant odor" generated during sterilization of culture media etc.
It melts smoothly in the sterilization process and exerts a deodorization effect.
Standard amount of deodorant according to the autoclave capacity
less than 40 L: 2-3 T at once
from 40 L to 60 L: 4 T at once
from 60 L to 100 L: 6 T at once
100 T / bottle
Sterilization tape, Sterilization label, Sterilization bag
Sterilization tape: Clear color change makes it easy to identify exposure to sterilization process.
Sterilization label: Paste directly on the object to be sterilized, you can check the sterilization treatment. After sterilization, the letters "sterilized" appear and it can be easily distinguished from untreated materials.
Sterilization bag: There are sterilization bags that are made of paper, roll type or one seal back type. Most of them are heat seal type, but tape seal type and aluminum plate seal type can be also available.
Ask us for prices and more details.
Specifications
Product name
HICLAVE HV series
Model
HV-50
HV-85
HV-110
Effective capacity
50 L
85 L
110 L
Chamber size (φ x H mm)
300 x 710
420 x 615
420 x 795
Operation mode
4 modes (LIQUID with warming, LIQUID without warming, SOLID, DISSOLUTION), one memory for each mode
Temperature
setting range
Sterilization
105°C - 135°C Variable
Dissolution
60°C - 100°C Variable
Warming
45°C - 60°C Variable
Time setting
range
Sterilization
1 min - 250 min, Remaining time is displayed
Dissolution
1 min - 60 min, Remaining time is displayed
Warming
20 h, fixed
Auto-start
Program autoclave to start 1 min to 1 week later
Exhaust setting
0% - 100%, Valve opening degree setting for LIQUID mode
Maximum working pressure
0.26MPa
Thermometer
5°C - 137°C
Pressure gauge
0MPa - 0.4MPa
Safety devices
Pressure safety valve, Over-current and earth leakage breaker, Low water cut off device
Alarms, error display
Low water heating, Temperature sensor wire disconnection, Over-temperature, Over-cool, Over-pressure,
Abnormality in lid opening / closing lever lock
Outside dimensions (W x D x H mm)
547 x 532 x 1046
667 x 652 x 1011
667 x 652 x 1191
Weight (Approximately)
57 kg
71 kg
81 kg
Pressure vessel category
Small sized pressure vessel
Chamber material
Stainless steel (SUS304)
Power supply
AC100V / 120V / 220V / 230V / 240V,
50Hz / 60Hz
(Specify voltage when ordering.)
AC220V / 230V / 240V,
50Hz / 60Hz
(Specify voltage when ordering.)