Materials used for pipette body have high tolerance to solvents.
Non-grease designed. No need to worry about continuous autoclaving.
2. Easy calibration
Easy calibration with enclosed jig.
3. Plunger
Ceramic plunger is used to prevent from corrosion by solvents.(200uL-10000uL)
4. O-ring
Chemical-guard O-ring with minimum expansion ratio.
5. Resin-made ejector pipe
Resin material of ejector pipe could enhance high tolerance to solvents.
6. Hyper Blower system
Hyper blower system improves dispensing efficiency, especially on 2μL and on 10μL dispensing.
Chemical Resistant Model of Nichipet Series
Advanced durability against organic solvent dispensing.
PTFE (Fluorine resin) in the air tight chamber of the instrument.
A Perfluoro rubber O-ring with low cubical expansion in the airtight parts.
All models have plungers made in materials resistant to organic solvents.
Hyper Blower System; a longer push stroke from the second stop position, to improve dispensing efficiency. (2μL, 10μL)
Fully autoclavable. (121°C for 20 minutes)
Enhanced UV resistance for better use in UV hoods.
Easy-Calibration function provides simple lab calibration.
Ceramic plungers are used for volume models from 200μL to 10000μL.
The one-touch locking mechanism makes it easy to lock the sample volume.
Specifications
Cat. No
Volume Setting
Volume range(μL)
Increments(μL)
Usable tips
00-NPLO2-2
Digital Setting
0.1~2
0.002
BMT2-UT/UTWR, FUT/FUTRB
00-NPLO2-10
0.5~10
0.01
BMT2-SSW/SSWR/SSWRB,
FSS/FSSRB
00-NPLO2-20
2~20
0.02
BMT2-SG/SGR, SE/SER, FSG/FSGRB
00-NPLO2-100
10~100
0.1
BMT2-SG/SGR, SE/SER, FSG/FSGRB*, FSE/FSERB
00-NPLO2-200
20~200
0.2
BMT2-SG/SGR, SE/SER, FSE/FSERB*, FAG/FAGRB
00-NPLO2-1000
100~1000
1
BMT2-LG/LGR, LE/LER, FLG/FLGRB, FLE/FLERB
00-NPLO2-5000
1000~5000
10
BMT2-X/XR
00-NPLO2-10000
1000~10000
10
BMT2-Z/ZR
AC & CV
Cat. No
Volume(μL)
Accuracy(%)
Precision(%)
00-NPLO2-2
0.2
±12.0 *
≤6.0 *
1
±5.0
≤2.5
2
±3.0
≤1.0
00-NPLO2-10
1
±4.0
≤3.0
5
±1.0
≤1.0
10
±1.0
≤0.5
00-NPLO2-20
2
±5.0
≤3.0
10
±1.0
≤1.0
20
±1.0
≤0.4
00-NPLO2-100
10
±2.0
≤1.0
50
±1.0
≤0.3
100
±0.8
≤0.3
Cat. No
Volume(μL)
Accuracy(%)
Precision(%)
00-NPLO2-200
20
±1.0
≤0.5
100
±0.8
≤0.3
200
±0.8
≤0.2
00-NPLO2-1000
100
±1.0
≤0.5
500
±0.8
≤0.3
1000
±0.7
≤0.2
00-NPLO2-5000
1000
±1.0
≤0.3
2500
±0.8
≤0.3
5000
±0.6
≤0.2
00-NPLO2-10000
1000
±2.0
≤0.4
5000
±0.8
≤0.3
10000
±0.4
≤0.2
*The AC and CV values below 0.2μL depend much on the operator’s skill and the environment under which the pipette is used.
*The AC and CV values are the values by use of the disposable tips described in the catalogue.
*The specification and price are subjected to change without notice due to modifications for quality improvement.
*The Nichipet EX Plus II is made of parts resistant to organic solvents which makes it more durable than previous pipettes in environments with organic solvents. However, it does not guarantee accuracy of dispensing organic solvents.
*As the body of the Nichipet EX Plus II is not resistant to organic solvents, make sure it does not come in contact with the organic solvents.